Showing posts with label pump. Show all posts
Showing posts with label pump. Show all posts
Tuesday, March 26, 2013
AIR CONDITIONER HEAT PUMP SERVICE MANUAL
This Service Manual is the result of the dedication of The Dometic Corporation and its engineers to providing service people the necessary instructions for making accurate analysis of certain conditions. Provided is a comprehensive guide designed to lead a qualified mechanic through the Service Manual to locate and solve symptoms that may occur. Dometic continues their commitment to providing the most up to date information about servicing Duo-Therm Air Conditioners and Heat Pumps,Make sure that the power supply to the unit is disconnected before performing any work on the unit to avoid the possibility of shock injury or damage to the equipment. The unit is to be protected by a time delay fuse or HACR (heating, air conditioner, refrigerator) breaker. By taking an amp reading at the unit AC voltage supply line, you can determine if the breaker is tripping prematurely. Place a clamp-on type ammeter around the black wire between the unit and breaker. Turn ON the unit and record the amp draw. If the breaker trips before the rated amperage, replace the breaker.
Download: Air Conditioner Heat Pump Service Manual
Download: Air Conditioner Heat Pump Service Manual
Monday, March 25, 2013
Putt Pump Hydraulic Head Crimper Instruction Manual
The force of escaping hydraulic fluid could cause serious injury. Do not subject the hose to potential hazard such as fire, extreme heat or cold, sharp surfaces, or heavy impact. Do not allow the hose to kink, twist, curl, or bend so tightly that the oil flow within the hose is blocked or reduced. Periodically inspect the hose for wear because any of these conditions can damage the hose and possibly result in personal injury.Hose material and coupler seals must be compatible with the hydraulic fluid used. Hoses must not encounter corrosive materials such as creosote-impregnated objects and some paints. Consult the manufacturer before painting a hose. Never paint the couplers. Hose deterioration due to corrosive materials may result in possible personal injury. The Molex Putt Pump Hydraulic Head Crimper is designed to crimp 8 to 4/0 AWG insulated and uninsulated terminals and splices. Crimps a wide range of products with interchangeable tool kits, which reduce the overall cost and provide production flexibility.Select the 1/4 NPT threaded fittings that are compatible with your air supply. 2. Remove the red plastic thread protector from the putt pump on the air connection. Pull out and discard then attach the air fitting. 3. Next, install the fittings to the filter, regulator, and gauge unit. The air supply should be 20 CFM (550 L/M) and 100 PSI (6.9 Bars) to obtain the rated hydraulic output. Air pressure should be regulated to a maximum of 125 PSI (8.6 Bars). See Figure 3-1. 4. Before installing the hydraulic hose, unscrew the square nut on the putt pump outlet and discard. Attach the hose assembly to the hydraulic fluid outlet.
Download: Putt Pump Hydraulic Head Crimper Instruction Manual
Download: Putt Pump Hydraulic Head Crimper Instruction Manual
Subscribe to:
Posts (Atom)